FILLCONTROL Monitor is a comprehensive process monitoring module and serves as the basis for all PRIAMUS® systems. It offers the possibility of simple bad part separation such as the removal of individual bad parts with the help of individual alarm signals
In addition, FILLCONTROL Monitor offers the opportunity of detecting the melt position in the cavity, switching over to holding pressure automatically or via switching level and monitoring viscosities.
The quality-dependent monitoring parameters are divided into warning, intervention and alarm limits.
Application |
---|
Good / bad part separation |
Switchover to holding pressure via switching level |
Automatic switchover to holding pressure |
Viscosity monitoring |
Application | Problem | Example | Solution |
---|---|---|---|
General | Parts are not filled | Cable connector | Monitoring the pressure level |
Coinjection | Uncontrolled filling | Food container | Monitoring the sheer rate |
Family molds | Different length of flow paths | Model kits | Monitoring the individual cavities |